17 research outputs found

    A Miniature Acoustic Device for Tracking Small Marine Animals or Submerged Drifters

    Get PDF
    This paper presents an acoustic archival tag capable of tracking small marine animals. It is also a technology that can be ported to other platforms, such as the next-generation acoustic and Argo floats as well as gliders. Tracking is achieved by standard RAFOS triangulation using the arrival times of unique sound signals emitted by moored sources. At the core of the tag is a custom microchip that controls all system operations. It incorporates the critical acoustic arrival time detector, a thermal sensor, and a pressure sensor interface. All the electronic components are housed inside a cylindrical hydrophone of 25.4-mm length and 10.7-mm diameter. The collected data are archived in nonvolatile memory chips with a total capacity of 4 Mb, sufficient storage to record position, temperature, and pressure on an hourly basis for 2 years. The tag consumes 4–5 μW in standby mode and between 60 and 90 μW while the sound arrival time detector is in operation. The power is provided by two button cell silver-oxide batteries, which enable an active tag lifetime of approximately 2 years

    THE DIAMOND HEMESEP BLOOD PROCESSING UNIT: A REAL-TIME MICROFLUIDIC WHOLE BLOOD SEPARATION PROCESS

    Get PDF
    Recent advancements in the field of microfabrication and microfluidics have made possible the design of separation devices and clinical diagnostic kits that use relatively smaller volumes of sample material than existing technologies. Using this technology, as well as existing technologies in membrane and immunomagnetic separations, a novel blood processing unit based on microfluidics has been designed. This report will detail the operation and layout of a microfluidic chip that produces three outputs (serum, plasma and a white blood cell lysate) from a human whole blood input. Microfluidic technology has allowed for the design of several distinctive features that make the performance of the blood processing unit comparable to existing centrifuge technologies available clinically and in research laboratories. Among other features, the chip produces a stabilized white blood cell lysate and is designed to match the blueprint of existing 96-well plates. In addition to describing the on-board processes and features of the chip, this report will also discuss the components needed for operation of the chip as well as a process to manufacture the product. This product, known as the Diamond HemeSep blood processing unit, could offer more standardized, efficient blood separation technologies that would benefit health care providers, patients and researchers. Moreover, the product is predicted to have a healthy financial outlook: based on the target market of clinical laboratories performing preclinical and clinical trials involving numerous samples of blood, we expect to sell 1 million cartridges in the first year of production with sales growing to 1.7 million cartridges in the tenth and final year. The net present value (NPV) of the proposed project, based on a selling price of 25acartridge,isexpectedtobe25 a cartridge, is expected to be 51 million. For the current projections, Series A investors can expect returns of 45%

    Quantifying and Optimizing Single-Molecule Switching Nanoscopy at High Speeds

    No full text
    <div><p>Single-molecule switching nanoscopy overcomes the diffraction limit of light by stochastically switching single fluorescent molecules on and off, and then localizing their positions individually. Recent advances in this technique have greatly accelerated the data acquisition speed and improved the temporal resolution of super-resolution imaging. However, it has not been quantified whether this speed increase comes at the cost of compromised image quality. The spatial and temporal resolution depends on many factors, among which laser intensity and camera speed are the two most critical parameters. Here we quantitatively compare the image quality achieved when imaging Alexa Fluor 647-immunolabeled microtubules over an extended range of laser intensities and camera speeds using three criteria – localization precision, density of localized molecules, and resolution of reconstructed images based on Fourier Ring Correlation. We found that, with optimized parameters, single-molecule switching nanoscopy at high speeds can achieve the same image quality as imaging at conventional speeds in a 5–25 times shorter time period. Furthermore, we measured the photoswitching kinetics of Alexa Fluor 647 from single-molecule experiments, and, based on this kinetic data, we developed algorithms to simulate single-molecule switching nanoscopy images. We used this software tool to demonstrate how laser intensity and camera speed affect the density of active fluorophores and influence the achievable resolution. Our study provides guidelines for choosing appropriate laser intensities for imaging Alexa Fluor 647 at different speeds and a quantification protocol for future evaluations of other probes and imaging parameters.</p></div

    Effect of photoswitching dynamics on the density of active fluorophores.

    No full text
    <p>(<b>A, B</b>) Fraction of Alexa Fluor 647 molecules in the ON-state (the singlet state, S) and the OFF-states (the triplet state, T, the dark state, D and the long-lived dark state, LLD) over time upon irradiation with 31 kW/cm<sup>2</sup> (<b>A</b>) and 2 kW/cm<sup>2</sup> (<b>B</b>) of 642-nm light. The horizontal black lines mark the threshold for the optimal fraction of fluorophores in the ON-state, which corresponds to the optimal density of active fluorophores (1 active fluorophore per 700 nm length of microtubule) in the case of an artificial microtubule as illustrated in <b><a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0128135#pone.0128135.g008" target="_blank">Fig 8 A</a></b>. (<b>C</b>) The fraction of fluorophores in the ON-state at equilibrium at different excitation intensities.</p

    Effect of laser intensity on Alexa Fluor 647 photoswitching kinetics.

    No full text
    <p>(<b>A</b>) Model of Alexa Fluor 647 photoswitching mechanism [<a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0128135#pone.0128135.ref020" target="_blank">20</a>, <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0128135#pone.0128135.ref021" target="_blank">21</a>]. Upon irradiation, the fluorophore can undergo intersystem crossing and switch from the fluorescence-emitting ON-state to the triplet state with rate <i>k</i><sub><i>12</i></sub>. The triplet state (T) can either recover to the singlet ground state or react with a thiolate to form the radical anion of the fluorophore (dark state, D). The dark state can be oxidized to recover to the singlet ground state or form a thiol adduct [<a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0128135#pone.0128135.ref022" target="_blank">22</a>] (long-lived dark state, LLD). (<b>B—G</b>) Photoswitching rates at different excitation laser intensities extracted from single-molecule experiments. At low intensities (1.0–16 kW/cm<sup>2</sup>, blue dots), data were recorded at 200 fps to allow for high temporal resolution and high signal-to-noise ratio. At high intensities (31–97 kW/cm<sup>2</sup>, red triangles), data were recorded at 800 fps because the ON-state lifetime is reduced to a few milliseconds and requires higher temporal resolution.</p

    Effect of photobleaching on localization density at different laser intensities.

    No full text
    <p>(<b>A</b>) Localization density accumulated with three pairs of imaging parameters over long term imaging (160,000–400,000 frames per data set). (<b>B, C</b>) Total number of SMSN images obtained before the spatiotemporal resolution decreases due to photobleaching. (<b>B</b>) When imaging at 3.9 kW/cm<sup>2</sup> and 50 fps with 405-nm light, 46 SMSN images were generated with a localization density of ~800 localizations per 1 μm MT and temporal resolution of 100 s per image. (<b>C</b>) When imaging at 31 kW/cm<sup>2</sup> and 800 fps with 405-nm light, 37 SMSN images were generated with the same localization density and improved temporal resolution of 5 s per image. Scale bars: 1 μm.</p

    The influence of single-molecule switching kinetics and camera frame rate on SMSN imaging.

    No full text
    <p>A schematic shows the accumulation of localized molecules over time for different scenarios. The fluorescence emission (red circles) of each molecule labeling a ring-like structure is fit to yield its position (black dots). Both fast switching kinetics and high camera speed are required for the most efficient localization of molecules (case III).</p
    corecore